Skip to content
aldarist

Eye-movement testing made accessible to everyone.

We’re building affordable medical assessment equipment that clinics can understand, repair and upgrade, with open-source software at its core. We’re starting with video oculography: two sets of goggles for vestibular and eye-movement testing.

Simulated recording · right-beating nystagmus

Slow-phase velocity 2.2°/s

Horizontal ↑ right · ↓ left
Vertical ↑ up · ↓ down

Blackout off: the patient can see the room and fixates, which suppresses their nystagmus.

Illustrative signal, not patient data

Vestibular and visual disorders are common. The equipment to assess them isn’t.

1 / 3

Affordable to buy

Specialist assessment equipment, like video oculography, is priced for large hospital departments. Many clinics go without, and rely on bedside tests alone.

2 / 3

Transparent to verify

Closed, proprietary software makes it hard to check how a result was calculated. Ours publishes the method alongside the measurement.

3 / 3

Built to be repaired and upgraded

Standard parts, replaceable components and a modular design mean a system can be fixed or upgraded rather than replaced, and keep working long after its warranty.

Our first products: two goggles, for two jobs

Impulse and Orbit are where we’re starting. Begin with fast screening, add in-depth investigation when you need it. Both record into the same open analysis software.

Prototype

Impulse

Lightweight goggles for the video head impulse test.

Light enough to stay put during rapid head movements, so your results stay reliable and accurate. High FPS cameras allow for the newest testing methods.

01002003000100200300ms°/s
Head Eye Mean gain 0.97
Head and eye velocity across eight head impulses (simulated). Gain is eye velocity divided by head velocity.
  • Lightweight design prevents slippage and invalid results
  • Built-in head motion sensor
  • Lateral, LARP and RALP canal planes
  • Suppression head impulse (SHIMP) paradigm

In design

Orbit

Full-enclosure goggles for in-depth investigation.

Binocular cameras inside a light-tight enclosure for videonystagmography. Observe nystagmus without fixation, run positional and caloric tests, and record oculomotor tasks.

HorizontalVerticalTorsional
HorizontalVerticalTorsional
Three-axis eye position during a positional test (simulated).
  • Light-tight enclosure with switchable fixation target
  • A blackout cover to prevent fixation
  • Horizontal, vertical and torsional tracking
  • Positional, caloric and oculomotor protocols

Which goggles do I need?

Impulse screens. Orbit investigates. Both record into the same analysis software.

FeatureImpulseOrbit
Best forScreeningFull investigation
Fixation removal (Blackout) No
Video head impulse test (vHIT) Yes No
Suppression head impulse (SHIMP) Yes No
Spontaneous and gaze-evoked nystagmusWith fixation Yes
Positional tests (Dix–Hallpike, supine roll) No Yes
Caloric testing No Yes
Saccades, smooth pursuit, optokinetic No Yes

Open and repairable

Our analysis software is open source, and we’re opening up our designs as they mature, so clinicians, engineers and researchers can see how it works. Everything is built to be serviced and upgraded, so a unit stays in use for years rather than being replaced.

Planned licence: GPL-3.0 for our analysis software.

See our work on GitHub
Analysis software
Recording, pupil tracking, gain and nystagmus analysis, and clinical reports.
Hardware
Enclosures, optics mounts and mechanical parts in open CAD formats.
Firmware
Camera capture, illumination control and head motion sensing.
Validation
Test protocols and comparison data from our bench and clinical studies.
Repair
Service guides, standard parts and replaceable modules, so clinics and local technicians can keep units running.

Where we are

  1. Prototype goggles

    In progress

    Working Impulse prototypes, camera pipeline and first analysis software.

  2. Bench validation

    Measure tracking accuracy against reference systems and publish the results.

  3. Clinical evaluation

    Pilot studies with clinicians to test usability and agreement with current practice.

  4. UKCA marking

    Complete conformity assessment under UK medical device regulations.

  5. Orbit, then beyond

    Bring Orbit through the same process, then take the same open, repairable approach to our next assessment instruments.

Help shape the first release

We’re looking for audiologists, ENT and neurology clinicians, vestibular physiotherapists and researchers to try early units, tell us what’s missing, and help decide what we build next.

Email the team